Flammable liquid
A flammable liquid is a liquid which can be easily ignited in air at ambient temperatures, i.e. it has a flash point at or below nominal threshold temperatures defined by a number of national and international standards organisations.
The Occupational Safety and Health Administration (OSHA) of the United States Department of Labor defines a liquid as flammable if it has a flash point at or below 93 °C/199.4 °F.[1] Prior to bringing regulations in line with the United Nations Globally Harmonized System of Classification and Labeling of Chemicals (GHS) in 2012, OSHA considered flammable liquids to be those with a flash point below 37.8 °C/100 °F. Those with flash points above 37.8 °C/100 °F and below 93.3 °C/200 °F were classified as combustible liquids.[2][3] Studies show that the actual measure of a liquid's flammability, its flash point, is dependent on the local air pressure, meaning that at higher altitudes where the air pressure is lower, the flash point is also lower.[4]
Categorization
Both OSHA and GHS further divide flammable liquids into 4 categories:
- Category I flammable liquids are those with boiling points ≤ 35 °C/95 °F and flash points < 23 °C/73 °F[1][5]
- Category II flammable liquids are those with boiling points > 35 °C/95 °F and flash points < 23 °C/73 °F[1][5]
- Category III flammable liquids are those with flash points > 23 °C/73 °F and ≤ 60 °C/140 °F[1][5]
- Category IV flammable liquids are those with flash points > 60 °C/140 °F and ≤ 93 °C/199.4 °F[1][5]
These categorizations are dependent upon a set altitude and atmospheric pressure, as both boiling point and flash point change with changes in pressure.[4]
Labeling
Both GHS and OSHA require the labeling of flammable liquids, on containers and safety data sheets, as follows:[3][5]
Category I | Category II | Category III | Category IV | |
---|---|---|---|---|
Symbol | Flame | Flame | Flame | none |
Signal Word | Danger | Danger | Warning | Warning |
Hazard Statement | Extremely flammable liquid and vapour | Highly flammable liquid and vapor | Flammable liquid and vapour | Combustible liquid |
See also
- Fire prevention
- Fire protection
- Flammability
- List of R-phrases
References
- ^ a b c d e "1910.106 - Flammable liquids. | Occupational Safety and Health Administration". www.osha.gov. Retrieved 2019-03-06.
- ^ "But It Wasn't Flammable Before! GHS Changed the Meaning of 'Flammable Liquids'". EHS Daily Advisor. 2015-09-23. Retrieved 2019-03-08.
- ^ a b "HCS/HazCom 2012 Final Rule & Appendices | Occupational Safety and Health Administration". www.osha.gov. Retrieved 2019-03-08.
- ^ a b Ding, Chao; Yao, Wei; Tang, Yanfei; Rong, Jianzhong; Zhou, Dechuang; Wang, Jian (March 2014). "Experimental study of the flash point of flammable liquids under different altitudes in Tibet plateau". Fire and Materials. 38 (2): 241–246. doi:10.1002/fam.2177. S2CID 137412493.
- ^ a b c d e Globally harmonized system of classification and labelling of chemicals (GHS). United Nations. Economic Commission for Europe. Secretariat. (Seventh revised ed.). New York. 2017. ISBN 9789211171310. OCLC 994197992.
{{cite book}}
: CS1 maint: location missing publisher (link) CS1 maint: others (link)
- v
- t
- e
- Backdraft
- Boiling liquid expanding vapor explosion (BLEVE)
- Boilover
- Combustibility and flammability
- Conflagration
- Dangerous goods (HAZMAT)
- Deflagration
- Detonation
- Dust explosion
- Enthalpy of vaporization
- Explosive
- Fire class
- Fire control
- Fire loading
- Fire point
- Fire triangle
- Flammability diagram
- Flammability limit
- Flammable liquid
- Flashover
- Flash point
- Friction loss
- Gas leak
- Heat transfer
- Jet fire
- K-factor (fire protection)
- Pool fire
- Pyrolysis
- Spontaneous combustion
- Structure fire
- Thermal radiation
- Water pressure
- Active fire protection
- Automatic fire suppression
- Condensed aerosol fire suppression
- Detonation flame arrester
- External water spray system
- Fire bucket
- Fire prevention
- Fire protection
- Fire retardant
- Fire-retardant fabric
- Fire retardant gel
- Fire-safe polymers
- Fire safety
- Fire sprinkler system
- Fire suppression system
- Firefighting foam
- Flame arrester
- Flame retardant
- Flashback arrestor
- Fusible link
- Gaseous fire suppression
- Hypoxic air technology for fire prevention
- Inerting system
- Intumescent
- Passive fire protection
- Personal protective equipment (PPE)
- Relief valve
- Spark arrestor
- Tank blanketing
- Vehicle fire suppression system
- Annulus (firestop)
- Area of refuge
- Booster pump
- Compartmentalization (fire protection)
- Crash bar
- Electromagnetic door holder
- Electromagnetic lock
- Emergency exit
- Emergency light
- Exit sign
- Fire curtain
- Fire cut
- Fire damper
- Fire door
- Fire escape
- Fire extinguisher
- Fire hose
- Fire hydrant
- Fire pump
- Fire sprinkler
- Firestop
- Firestop pillow
- Firewall (construction)
- Grease duct
- Heat and smoke vent
- Occupancy
- Packing (firestopping)
- Penetrant (mechanical, electrical, or structural)
- Penetration (firestop)
- Pressurisation ductwork
- Safety glass
- Smoke control
- Smoke damper
- Smoke exhaust ductwork
- Smokeproof enclosure
- Standpipe (firefighting)
and services
- Template:Fire
- Template:Firefighting
- Template:HVAC
- Category
- Commons
This explosives-related article is a stub. You can help Wikipedia by expanding it. |
- v
- t
- e